International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 119 | Views: 223

Research Paper | Medical Surgical | India | Volume 6 Issue 7, July 2017 | Popularity: 6.8 / 10


     

Comparative Analysis of Optical Biometry and Conventional Ultrasound A-Scan for Biometric Calculations of Eye

Bhairavi S Raut, Meena G Menon, Umesh Y


Abstract: Title Comparative analysis of optical biometry and conventional ultrasound a-scan for biometric calculations of eye Aim To evaluate the predictability of refractive outcome using optical and ultrasound biometry in getting near emmetropia post operatively and to compare the axial length (AL), intraocular lens (IOL) power measured with Lenstar LS 900 with those obtained with ultrasound a-scan (Echorule2, Biomedix) in cataract patients. Material & methods After proper clearance from the ethical committee, the data of 231 eyes of 138 adult patients who had undergone surgery for visually significant cataract in one or both eyes at our centre was analyzed retrospectively for the study. Every eye had undergone two measurements each with an optical biometer (OS) (Lenstar, Haag Striet) and with ultrasound A-scan (UAS) (Echorule2, Biomedix). Optical biometry was performed first followed by ultrasound measurements. SRK-T formula was used for calculation of IOL power. Results The mean axial length of measured with OS was 23.46 1.50 mm (range, 20.62-31.87mm) and that measured with UAS was 23.37 1.52mm (range, 20.2-32.29mm). The axial lengths were compared using independent t-test, the p-value (0.526) was not found to be statistically significant and the mean difference was 0.089. The mean IOL measured with OS was 20.67 4.35D and that measured with UAS was 20.86 4.32D. The IOL powers were compared using independent t-test, the p-value (0.63) was not found to be statistically significant and the mean difference was -0.19. The BlandAltman plots showed good agreement between devices with less than 5 % of eyes that were outliers. In both the groups, majority of the patients had spherical equivalents within 1D. On comparison, the post-operative refraction was not statistically significant. Conclusion Optical biometry with OCLR technology to measure axial length is very precise and interchangeable with ultrasound measurement with no clinical difference in post-operative refraction in cataract patients.


Keywords: Biomedix, Lenstar, Axial length, IOL


Edition: Volume 6 Issue 7, July 2017


Pages: 674 - 677




Text copied to Clipboard!
Bhairavi S Raut, Meena G Menon, Umesh Y, "Comparative Analysis of Optical Biometry and Conventional Ultrasound A-Scan for Biometric Calculations of Eye", International Journal of Science and Research (IJSR), Volume 6 Issue 7, July 2017, pp. 674-677, https://www.ijsr.net/getabstract.php?paperid=ART20174765

Similar Articles

Downloads: 1 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Case Studies, Medical Surgical, Argentina, Volume 12 Issue 12, December 2023

Pages: 960 - 963

Atypical Parathyroid Tumor in an Ectopic Gland- Case Report

D'Addino Jose, Paredes Julieta, Grosso Cristina

Share this Article

Downloads: 136 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Medical Surgical, Iraq, Volume 5 Issue 7, July 2016

Pages: 774 - 777

Epidemiological Analysis of the Nasal Trauma

Mohammed Radef Dawood

Share this Article

Downloads: 0

Survey Paper, Medical Surgical, Albania, Volume 11 Issue 5, May 2022

Pages: 1551 - 1556

Surgery for Non Small Cell Lung Cancer - A Systematic Review

Ilir Skenduli, Perlat Kapisyzi

Share this Article

Downloads: 0

Case Studies, Medical Surgical, India, Volume 11 Issue 9, September 2022

Pages: 514 - 516

Laparoscopic Cholecystectomy in a New Way

Dr. Sunny Singh, Dr. Mrityunjai Kumar, Dr. Sashi Kant Joshi

Share this Article

Downloads: 0

Student Project, Medical Surgical, India, Volume 11 Issue 10, October 2022

Pages: 855 - 857

A Descriptive Study to Assess the Knowledge and Practice regarding Prevention of COVID-19 among School Going Children in Selected Schools, Kolhapur

Neeta Ranbhise

Share this Article
Top