Calibration of Survey Meters at the Secondary Standards Dosimetry Laboratory at the Radiation Protection Institute of Ghana Tomic Energy Commission

J. Owusu-Banahene [3] | E.O Darko | P. Appiah | P. Owusu-Manteaw


Abstract: Some digital and analogue radiation surveys meter have been calibrated at the Secondary Standard Dosimetry Laboratory at Radiation Protection Institute of Ghana Atomic Energy Commission using Cs-137 radiation source. All the survey meters were a total of ten having the ratio of 2: 8 indicating 20 % were analogue whereas 80 % were digital survey meters. Calibration of radiation survey meter instruments is a process which may be conducted with varying degrees of accuracy and precision. Both are a function of the facilities and equipment, time, personnel and financial resources available to perform the calibration. Proper care of radiation detecting and measuring equipment, as with all equipment, is the primary mechanism for ensuring its proper functioning. Radiation measuring devices need to process calibration, which might lose their sensitivity and extent of the response and the amount of stability under a changing condition from time to time in which this period depends on the nature and the use of radiation field in which the device is used. For all the selected radiation survey meters brought to Secondary Standards Dosimetry Laboratory, the radiation survey meter from the company S5 had the highest response whereas the survey meter from S8, had the lowest response hence the highest calibration factor.


Keywords: Calibration, Dose rate, Radiation, Response and Instrument


Edition: Volume 8 Issue 1, January 2019,


Pages: 1386 - 1391


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

J. Owusu-Banahene, E.O Darko, P. Appiah, P. Owusu-Manteaw, "Calibration of Survey Meters at the Secondary Standards Dosimetry Laboratory at the Radiation Protection Institute of Ghana Tomic Energy Commission", International Journal of Science and Research (IJSR), Volume 8 Issue 1, January 2019, pp. 1386-1391, https://www.ijsr.net/get_abstract.php?paper_id=ART20194344

Similar Articles with Keyword 'Calibration'

Downloads: 115

Research Paper, Physics Science, Iraq, Volume 7 Issue 2, February 2018

Pages: 1223 - 1226

Preparation and Measurement of Soil Standard Source as a Petri Dish Using 152EuIsotope

Khalid H.AL-Ubaidi | Salam K.AL-Nasri | Kawthar H. AL-Jelehawy

Share this Article

Downloads: 118

Research Paper, Physics Science, Nigeria, Volume 4 Issue 8, August 2015

Pages: 1055 - 1061

Energy and Efficiency Calibrations for High Purity Germanium GEM30195 Coaxial Detector USING k0-IAEA Software

Joseph E. [2] | Nasiru R. | Sadiq U. | Ahmed [872] | Y. A. [10]

Share this Article
Top