Downloads: 118 | Views: 347
Research Paper | Radiological Sciences | Saudi Arabia | Volume 4 Issue 3, March 2015 | Popularity: 6.6 / 10
Optimization of PAVAgNO3 Films for Measuring Entrance and Exit Radiotherapy Dose Relative to TLDs
Mohammed A. Ali Omer, Hamed A. Ismail, Mohamed E. M. Garlnabi, Ghada A. Edam, Nuha S. Mustafa
Abstract: The aim of this study was to synthesize the PVAAgNO3 polymer films and to optimize it is radiation measurement based on entrance and exit dose measurement relative to thermoluminiscence detector (TLD) method. The polymer films have been synthesized by casting technique after dissolving of polyvinyl alcohol (PVA) under controlled temperature (80 C) and stirring and hybridization with silver nitrate (AgNO3). The polymer films have been characterized after irradiation at the entrance and exit sites of Perspex by UV-visible spectroscopy and an optical densitometer (OD). The study revealed that there were absorption peaks at wavelength () 190 and 425 nm related to pure PVA and silver out of UV-visible spectroscope, and the average entrance and exit doses read by TLD was 7.064.7 and 3.982.8 Gy and they are usually less than the applied dose by an average factor of 0.22 and 3.3 Gy respectively, also there is a linear proportional and significant (R2 = 0.9) relationship between the applied dose and the measured OD at entrance and exit side of the phantom that could be fitted in the following equation y = 0.040x + 0.117 and y = 0.031x + 0.099 respectively, where x refers to the applied dose and y refers to the OD at the entrance and exit sides of the phantom. Also there is a linear proportional and significant (R2 = 0.9) relationship between the entranceexit doses measured by TLD and the relative OD at both sides of the phantom which could be fitted in the following equation y = 0.035x + 0.159 and y = 0.027x + 0.132 respectively, where x refers to the entranceexit doses and y refers to the entranceexit OD and the attenuation coefficient of Perspex (phantom) has been derived correctly from the relationship between the phantom thickness and its absorption coefficient which was 0.1670 cm-1.
Keywords: PVAAgNO3, Film Dosimeter, Radiotherapy, EntranceExit dose
Edition: Volume 4 Issue 3, March 2015
Pages: 1279 - 1282
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 105
Survey Paper, Radiological Sciences, Egypt, Volume 4 Issue 4, April 2015
Pages: 1316 - 1319Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine
Allehyani S. H., Taha M.T., Bahashwan Y. M.
Downloads: 105
Research Paper, Radiological Sciences, Egypt, Volume 5 Issue 8, August 2016
Pages: 1309 - 1313Evaluation of the Role of Postmastectomy Radiotherapy in Women with One to Three Positive Auxillary Nodes with Extracapsular Invasion
Nabila Hezi. MD, Nadia Ali. MD
Downloads: 110
Research Paper, Radiological Sciences, Saudi Arabia, Volume 3 Issue 6, June 2014
Pages: 1694 - 1698Estimation of Dose Received by Sensitive Organs in External Radiation Therapy of Cervical Carcinoma
Mohamed E. M. Gar-Alnabi, Enaam A. Mohamed, Mohamed A. Ali Omer, Ghada A. E. Sakin, Mohammed Farahna
Downloads: 111
Review Papers, Radiological Sciences, India, Volume 6 Issue 7, July 2017
Pages: 1943 - 1944Effects of Radiation on Oral Tissues
Karpaga Preethitha.S
Downloads: 134 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Survey Paper, Radiological Sciences, Saudi Arabia, Volume 4 Issue 6, June 2015
Pages: 2791 - 2794Effects of Nasopharyngeal Cancer's Patients Irradiation in Thyroid Function
Mohamed E. M. Gar-Elnabi, Fadwa I. Mosa, Abdulrahman A. Alsiyyari, Ghada A. Edam, Mohammed A. Ali Omer