Downloads: 99 | Views: 288
Research Paper | Chemistry | India | Volume 6 Issue 7, July 2017 | Popularity: 6.4 / 10
RP-HPLC Method Development and Validation for the Analyisis of Pharmaceutical Drug ? ACECLOFENAC
Ami R Patel, Dr. V G Patel
Abstract: A simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of ACECLOFENAC. Isocratic elution at a flow rate of 1.2 ml /min was employed on a symmetry C18 column at ambient temperature. The mobile phase consisted of Acetonitrile 0.1M Acetic Acid 6040 (v/v). The UV detection wavelength was at 210 nm. Linearity was observed in concentration range of 0.01-0.05 gm/ml. The retention time for ACECLOFENAC was 3.0 min. The method was validated as per the ICH guidelines. The proposed method can be successfully applied for the estimation of ACECLOENAC.
Keywords: Aceclofenac, Method Development, Validation, 210nm, 30min
Edition: Volume 6 Issue 7, July 2017
Pages: 1318 - 1320