Downloads: 180
Research Paper | Surgery | Volume 13 Issue 12, December 2024 | Pages: 1483 - 1487 | India
Comparative Analysis of Cyanoacrylate Glue versus Suture Mesh Fixation in Lichtenstein's Inguinal Hernia Repair
Abstract: Lichtenstein's open tension - free inguinal hernia repair is a widely accepted surgical technique. The use of Cyanoacrylate glue for mesh fixation has emerged as a potential alternative to traditional suture fixation, offering the possibility of reduced operative time and improved patient outcomes. A Prospective Cohort study aimed to compare the clinical outcomes, including intraoperative and postoperative parameters, complications, and recovery profiles, between Cyanoacrylate glue mesh fixation and suture mesh fixation in Lichtenstein's inguinal hernia repair was carried out in Tertiary Care setting, which included 80 patients. Data were collected and analyzed using t - tests and chi - square tests, with a significance level of p
Keywords: Lichtenstein's inguinal hernia repair, Cyanoacrylate glue, Suture mesh fixation, Postoperative pain, Mesh fixation, Surgical outcomes
How to Cite?: Dr. Arun Jhade, Dr. Abhilash Kumar Pithawa, "Comparative Analysis of Cyanoacrylate Glue versus Suture Mesh Fixation in Lichtenstein's Inguinal Hernia Repair", Volume 13 Issue 12, December 2024, International Journal of Science and Research (IJSR), Pages: 1483-1487, https://www.ijsr.net/getabstract.php?paperid=SR241222150437, DOI: https://dx.doi.org/10.21275/SR241222150437