International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 116 | Views: 360

Research Paper | Medicine Science | Sudan | Volume 3 Issue 11, November 2014 | Popularity: 6.7 / 10


     

Assessment of 99mTc Dose Calibrator Performance in Nuclear Medicine Department

Ahmed Y. A. Mohamed, Magadha H.O. Mudthir, Yousif Mohamed Y. Abdallah


Abstract: Nuclear medicine uses many different radioactive isotopes for radiation diagnostics and for therapy. The amount of radioactivity has to be determined exactly before it is applied to a patient. The Dose calibrators have to measure the radioactivity of gamma and beta with different energies precisely for high quality imaging and for applying the right amount of radiation to treat disease. This study was carried out to assess the performance of dose calibrators which work in nuclear medicine departments in Khartoum state. Two departments were included in this study, Radiation and isotopes center of Khartoum (RICK) and Elnileen medical diagnostic center. Four quality control tests were carried out using two standard Radionuclides, 137Cs and 57Co, which were accuracy, constancy, linearity and geometry. All results that obtained from the study has been compared with the international standard (5 %) and the results showed that all dose calibrators has good performance and there is no need for any correction tables or factors or maintenance.


Keywords: Nuclear medicine, dose calibrator, quality control


Edition: Volume 3 Issue 11, November 2014


Pages: 36 - 39



Make Sure to Disable the Pop-Up Blocker of Web Browser


Text copied to Clipboard!
Ahmed Y. A. Mohamed, Magadha H.O. Mudthir, Yousif Mohamed Y. Abdallah, "Assessment of 99mTc Dose Calibrator Performance in Nuclear Medicine Department", International Journal of Science and Research (IJSR), Volume 3 Issue 11, November 2014, pp. 36-39, https://www.ijsr.net/getabstract.php?paperid=OCT14613

Similar Articles

Downloads: 0

Research Paper, Medicine Science, Sudan, Volume 13 Issue 2, February 2024

Pages: 896 - 899

Quality Control of Conventional X-Ray Machine at Najran University Hospital Radiology Department

Nuha Salih Mustafa, Hamed A Ismail

Share this Article

Downloads: 105

Research Paper, Medicine Science, Sudan, Volume 3 Issue 11, November 2014

Pages: 2768 - 2771

Segmentation of Thyroid Scintography Using Edge Detection and Morphology Filters

Yousif Mohamed Y. Abdallah, Eltayeb Wagiallah

Share this Article

Downloads: 107

Research Paper, Medicine Science, Sudan, Volume 3 Issue 9, September 2014

Pages: 2325 - 2329

Correction Preprocessing Method for Cardiac Scintography Images using Local Adaptive Filters

Eltayeb Wagiallah, Yasir Ahmed, Yousif Mohamed Y. Abdallah

Share this Article

Downloads: 110

Comparative Studies, Medicine Science, Egypt, Volume 4 Issue 9, September 2015

Pages: 1386 - 1391

Highlights in the Diagnostic Dilemma of Solitary Thyroid Nodule; Fine Needle Aspiration Cytology in Comparison of Isotope Thyroid Scan

Abeer M. Hafez, Yasser S.Sheta, Fawzy A. Elmessallamy, Elsayed A. Elgohary, Mansour Mursy

Share this Article

Downloads: 114

Research Paper, Medicine Science, Sudan, Volume 5 Issue 8, August 2016

Pages: 1200 - 1204

Characterization of Hepatobiliary Scintigraphy using Linear Equations

Aya Ahmed Saeed, M.E.M Gar-elnabi, M. Ahmed Saeed, A.H.A. Bakry

Share this Article
Top