Downloads: 141 | Views: 301 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Research Paper | Dental Science | India | Volume 9 Issue 1, January 2020 | Popularity: 7 / 10
Comparison of Canal Transportation and Remaining Dentin Thickness using Different NiTi Systems with CBCT - An in Vitro Study
Shireesha Thota, Jayaprada Reddy Surakanti, Ravichandra Polavarapu Venkata, Harikumar Vemisetty, Rajani Punna, Srujana Chandragiri
Abstract: Context: Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. This study evaluated the shaping ability of three different instrumentation techniques. Aims: The aim of this study was to compare canal transportation and remaining dentin thickness of hand NiTi K files, ProTaper and WaveOne rotary systems using CBCT. Settings and Design: This study was conducted in the Department of Conservative Dentistry & Endodontics, Kamineni Institute of Dental Sciences, Narketpally in association with the secunderabad dental imaging, Secunderabad. Methods and Material: 30 mesiobuccal roots of maxillary first molars were taken and assigned to 3 experimental groups (n=10). Pre instrumentation and post instrumentation CBCT images of root cross sections at 3, 5, 7 and 9mm from apex to the canal orifice were obtained. Canal transportation and remaining dentin thickness were evaluated using DICOM software. Statistical analysis used: Data was statistically analyzed using SPSS version 19.0 software, One-way analysis of variance and Post hoc comparison for statistical significance. Results: It was observed that ProTaper has shown significantly more canal transportation when compared to hand NiTi K files and WaveOne at all the sections. Hand NiTi K files has shown significantly more dentin thickness compared to ProTaper and WaveOne at all sections. Conclusions: The WaveOne NiTi system has maintained the canal anatomy with less amount of canal transportation when compared with the ProTaper system and Hand NiTi K flex files in the apical third.
Keywords: Canal transportation, Cone beam computed tomography, Nickel Titanium, ProTaper, Reciprocating motion, WaveOne
Edition: Volume 9 Issue 1, January 2020
Pages: 548 - 551
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 2 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Review Papers, Dental Science, India, Volume 12 Issue 3, March 2023
Pages: 275 - 278The History, Evolution and Metallurgical Innovations in NiTi Endodontic Rotary File System
Dr. Akash Azad, Dr. Shraddha Chokshi
Downloads: 118
Research Paper, Dental Science, India, Volume 7 Issue 4, April 2018
Pages: 1177 - 1181Comparative Evaluation of Three Different Rotary NiTi File System with Different Generation for Root Canal Centric Ability Using CBCT: An in-vitro Study
Dr. Kailash Attur, Dr. Kamal Bagda, Dr. Kiran Vachhani, Dr. Jigar Parmar, Dr. Vivek Solanki, Dr. Riza Mansuri
Downloads: 130
Research Paper, Dental Science, Iraq, Volume 6 Issue 5, May 2017
Pages: 1870 - 1877Shaping ability of Wave One, One Shape, Hyflex CM and Trushape 3D Nickel Titanium Rotary Instruments with Different Access Angles
Mohammed Hameed, Noor Nadhum