Downloads: 129 | Views: 291
Research Paper | Radiological Sciences | Iraq | Volume 6 Issue 8, August 2017 | Popularity: 7.1 / 10
Accuracy of Hopelight (Mammolight) Imaging in Detection of Breast Cancer
Dr. Abdullateef Aliasghar, Prof. Dr. Nada A S Alwan, Dr. Khaleel Ibraheem Mohson, Dr. Enam Azez Khalel
Abstract: Background hopelight (mammolight device) is a transillumination of breast tissue with low intensity light for detection of breast lesions, however, its value has not been well established. Objectives to determine the diagnostic accuracy and sensitivity of hopelight in detection of breast cancer with radiologic-pathologic correlation Patients and methods a prospective study was performed in Radiology department at the Oncology Teaching Hospital, Medical City Complex in Baghdad (the main tertiary referral public center for breast disease in Iraq). This study enrolled 100 females attending mammography and ultrasound unit for screening, diagnosis or follow up of breast lesions in the period from March 2014 to November 2014. Breast examination was initially performed for each patient by hand-held hopelight device followed by mammography and/or ultrasound study and results were classified from normal to highly suspicious breast lesions according to breast imaging reporting and data system (BIRADS) then fine needle aspiration cytology or biopsy was acquired for BIRADS-IV and BIRADS-V lesions for histopathological review and final diagnosis. Results demographic, clinical and imaging findings were reported and statistical analysis obtained and sensitivity, specificity and accuracy were 66.66 %, 51.06 % and 52 % respectively with 8 % positive predictive value and 96 % negative predictive value. False positive results were detected in 46 % of the patients whereas false negative outcomes were 2 %. Conclusions hopelight device cannot be safely used for screening of breast cancer and cannot be used alone because of high false positive outcome and low sensitivity, specificity and overall accuracy in detection of breast cancer.
Keywords: hopelight, mammolight, breast
Edition: Volume 6 Issue 8, August 2017
Pages: 1731 - 1734
Make Sure to Disable the Pop-Up Blocker of Web Browser
Similar Articles
Downloads: 101
Research Paper, Radiological Sciences, Egypt, Volume 5 Issue 8, August 2016
Pages: 1371 - 1375Accelerated Partial Breast Irradiation Versus Traditional Whole Breast Ir-radiation in Early Stage (I&II) Breast Carcinoma
Nabila Hefzi. MD, Nadia Ali. MD, Ayman F. Ahmed. MD
Downloads: 105
Research Paper, Radiological Sciences, Egypt, Volume 5 Issue 8, August 2016
Pages: 1309 - 1313Evaluation of the Role of Postmastectomy Radiotherapy in Women with One to Three Positive Auxillary Nodes with Extracapsular Invasion
Nabila Hezi. MD, Nadia Ali. MD
Downloads: 118
Review Papers, Radiological Sciences, Colombia, Volume 8 Issue 9, September 2019
Pages: 819 - 823Breast Uptake of Radioiodine in Non-breastfeeding Women
Brun-Vergara ML, Salinas E, Ucrs G.
Downloads: 121 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1
Research Paper, Radiological Sciences, Tanzania, Volume 6 Issue 5, May 2017
Pages: 2566 - 2568Effects of Collimator and Gantry on Dose Delivery Accuracy for Patients Undergoing Radiation Therapy of the Breast on Theratron Equinox 80 cm SSD
Shaid O Yusuph, Peter K Msaki, Wilbroad E Muhogora
Downloads: 124
Research Paper, Radiological Sciences, Saudi Arabia, Volume 3 Issue 11, November 2014
Pages: 439 - 445Breast Cancer Awareness among Saudi Females in Taif, Saudi Arabia
Rania Mohammed, Magda A. M. Mansour, Laila SH. Dorgham