International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 116

Research Paper | Medicine Science | Egypt | Volume 4 Issue 10, October 2015


The Influence of Implants Number and Distribution on the Load Transmitted to the Palate for Implant Assisted Maxillary Overdentures

Ahmed Abd Al-Hamid | Moustafa Abou Shelib | Ahmed Hussien


Abstract: Statement of problem There is little information as to how the number and distribution of implants affect the amount of load transmitted to the palate in implant-assisted maxillary overdentures. Purpose Evaluate the difference in the load transmitted to the palate at different implants number and distribution. Materials and methods six overdenture bases were fabricated to fit an average sized edentulous maxillary replica with different implants number and distribution using positioner attachments. A force-measuring sensor was used to measure the force transmitted to the palate when static force of 110 and 220 N were applied on the denture bases. Data were statistically analyzed. Results The mean (SD) of force transmitted to the palate was in its highest value when no implants (control group) were used (38.28 2.47), (80.68 2.62) N and lowest value when overdenture bases assisted by 8 implants (12.33 2.52), (26.60 2.55) N when static load were 110 and 220 N respectively. The amount of force transmitted to the palate from implant assisted maxillary overdenture bases significantly declined with increasing the number and the distance between the implants. Conclusion implant numbers and distributions had a significant effect on the load transmitted from implant assisted maxillary overdenture to the palate.


Keywords: Maxillary overdenture, implant number, implant distribution, load transfer, the palate


Edition: Volume 4 Issue 10, October 2015,


Pages: 332 - 339


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Ahmed Abd Al-Hamid, Moustafa Abou Shelib, Ahmed Hussien, "The Influence of Implants Number and Distribution on the Load Transmitted to the Palate for Implant Assisted Maxillary Overdentures", International Journal of Science and Research (IJSR), Volume 4 Issue 10, October 2015, pp. 332-339, https://www.ijsr.net/get_abstract.php?paper_id=SUB158293

Similar Articles with Keyword 'palate'

Downloads: 119 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Case Studies, Medicine Science, India, Volume 3 Issue 7, July 2014

Pages: 1089 - 1090

Necrotizing Sialometaplasia-A Diagnostic Dilemma

Ameya Bihani [3] | Jaini Lodha [2] | Arpit Sharma [3] | Nitish Virmani | Jyoti P Dabholkar

Share this Article

Downloads: 120

Research Paper, Medicine Science, India, Volume 4 Issue 12, December 2015

Pages: 273 - 275

Epidemiology of Cleft Lip and Palate in Pediatric Patients ? A Hospital Based Study

Dr. Arun Parikh [2] | Dr. Alka Rao

Share this Article
Top