International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 96

Research Paper | Power Engineering | India | Volume 4 Issue 1, January 2015


Enhancement of LVRT Capability of DFIG Wind Turbine by Using Advanced Control Strategy

PR. Manojprabu | V. Sudhagar


Abstract: In this paper, doubly fed induction generator (DFIG) based wind turbine (WT) low voltage ride through (LVRT) capability is enhanced by using advanced control strategy for the rotor side converter (RSC) and grid side converter (GSC) to meet grid code requirements. The conventional crowbar with constant resistance method is used to protect and improve the LVRT. However, its response varies accordingly to the voltage dip level. In addition conventional method may be over or under estimate fault in certain condition which results in damage to the converters and DFIG. The proposed advanced control strategy introduces the instantaneous DC link current of the RSC as compensating term on GSC control scheme to smooth the DC link voltage fluctuations during the grid at the point of common coupling (PCC). By using pitch control, the wind energy is captured as rotor inertia during faults which significantly reduce the oscillations in the stator and rotor currents and the DC bus voltage during fault, the remaining energy is available to the grid after fault clearance and also it ensures smooth release of the excessive inertia energy into the grid. A time domain model for the 1.5 MW DFIG test system with the decoupled dq controller is implemented using MATLAB/SIMULINK and its effectiveness has been demonstrated through various simulation cases. The proposed control strategy results compared with conventional crowbar method shows not only the enhancement of LVRT capability of DFIG, but also helps maintaining continuous active and reactive power control during the grid fault.


Keywords: Doubly fed induction generator DFIG, wind turbine, low voltage ride through LVRT, power system fault, MATLAB/Simulink


Edition: Volume 4 Issue 1, January 2015,


Pages: 1543 - 1550


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

PR. Manojprabu, V. Sudhagar, "Enhancement of LVRT Capability of DFIG Wind Turbine by Using Advanced Control Strategy", International Journal of Science and Research (IJSR), Volume 4 Issue 1, January 2015, pp. 1543-1550, https://www.ijsr.net/get_abstract.php?paper_id=SUB15572

Similar Articles with Keyword 'Doubly'

Downloads: 93

Research Paper, Power Engineering, India, Volume 3 Issue 4, April 2014

Pages: 778 - 782

Dynamic Behavior of DFIG Wind Energy Conversion System under Various Faults with ANN

Dhayanidhi.N | Muralidharan.D

Share this Article

Downloads: 109

Research Paper, Power Engineering, India, Volume 3 Issue 12, December 2014

Pages: 596 - 601

Risk Reduction of SSO and Enhance the Stability in DFIG Control Systems Using Multi-Input Multi-Output State Space Methodology

G. Rajeswari [2] | A. Anuradha [2]

Share this Article