International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 111

Research Paper | Electrical Engineering | India | Volume 4 Issue 4, April 2015


Real and Reactive Power Flow Analysis & Simulation with UPFC Connected to a Transmission Line

Subhash Chander Swami | Anurag Pandey


Abstract: The UPFC is a member of the FACTS family with very attractive features and it is a solid state controller which can be used to control active and reactive power flow in a transmission line. In this paper the performance of Unified Power Flow Controller (UPFC) is investigated in controlling the flow of power over the transmission line. This research deals with simulation of transmission line using UPFC to improve the real and reactive power flow control through a transmission line. In this research paper a Simulink Model is considered with UPFC model to evaluate the performance of single and double transmission line systems (33/22) kV. In the simulation study, the UPFC models ease the real time control and dynamic compensation of AC transmission system. It should be consider as real and reactive power compensation, capable of independently controlling voltage profile as well as the real and reactive powers in the line. The simulation model is tested for single and double transmission line systems with and without UPFC model in MATLAB/SIMULINK environment. By using a UPFC the oscillation introduced by the faults, the rotor angle and speed deviations can be damped out quickly than a system without a UPFC. It is also shown that a UPFC can control independently the real and reactive power flow in a transmission line.


Keywords: FACTS, OPF, Power system, UPFC, N-R method, power flow controller


Edition: Volume 4 Issue 4, April 2015,


Pages: 2178 - 2183


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Subhash Chander Swami, Anurag Pandey, "Real and Reactive Power Flow Analysis & Simulation with UPFC Connected to a Transmission Line", International Journal of Science and Research (IJSR), Volume 4 Issue 4, April 2015, pp. 2178-2183, https://www.ijsr.net/get_abstract.php?paper_id=SUB153544

Similar Articles with Keyword 'FACTS'

Downloads: 176 | Weekly Hits: ⮙2 | Monthly Hits: ⮙2

Comparative Studies, Electrical Engineering, India, Volume 8 Issue 4, April 2019

Pages: 1653 - 1658

Optimal Placement of Compensating Devices in Distribution System by Using PSO Algorithm

E. V. Vinay

Share this Article

Downloads: 5 | Weekly Hits: ⮙3 | Monthly Hits: ⮙3

Review Papers, Electrical Engineering, India, Volume 10 Issue 12, December 2021

Pages: 529 - 533

Importance of FACTS Devices in Power System

Sarbjeet Kaur | Dr. Surbhi Gupta [2]

Share this Article
Top