International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 102

Research Paper | Medicine Science | Sudan | Volume 4 Issue 3, March 2015


Evaluation of Radiation Dose Received By Patient during Cardiac Catheterization Procedure

Mohamed E. M. Gar-elnabi [9] | Abdoelrahman Hassan. A. B. | Abdoelrahman A. Ahmed | Mohamed Yousef [19]


Abstract: The current study intends to measure patient dose and estimate the radiation dose received for patient in (IC) procedures. The study was measured radiation doses to (212) patients during interventional cardiology procedures 161to coronary angiography (CA) and 51 to percutaneous coronary interventions (PCI) was carried out in this study patient doses were calculated from patient body characteristics and exposure parameters using dose area product (DAP) meters. The mean age of patients 57.42 11.65 was ranging (21to 86) years. The mean value of tube parameter was 86.17 8.32KVp, ranges (to 63 from 105) Kvp, 5.59 0.844mAs range (to 3.2 from 10.2) mAs. The mean duration time of fluoroscopy was 6.87 7.06 mentis and the number of films per procedure was 9.17 4.53 films, range was (3 to33) films. All the investigations were performed in same center and department. The DAP measured in this study was lower than the previous reported studies in the literature. Because they can be attributed to the use of high voltage, long distance between patient and ionizing radiation source in all examinations


Keywords: Cardiac Catheterization Procedure, Hassan, patient dose, dose area product


Edition: Volume 4 Issue 3, March 2015,


Pages: 2353 - 2356


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Mohamed E. M. Gar-elnabi, Abdoelrahman Hassan. A. B., Abdoelrahman A. Ahmed, Mohamed Yousef, "Evaluation of Radiation Dose Received By Patient during Cardiac Catheterization Procedure", International Journal of Science and Research (IJSR), Volume 4 Issue 3, March 2015, pp. 2353-2356, https://www.ijsr.net/get_abstract.php?paper_id=SUB152713

Similar Articles with Keyword 'patient dose'

Downloads: 96

Research Paper, Medicine Science, Saudi Arabia, Volume 2 Issue 6, June 2013

Pages: 372 - 378

A review Study on Patients Radiation Dose from Diagnostic Radiography

Nasr Aldeen N. khidir [2] | Mohamed Yousef [19] | Mohammed A. AliOmer [2] | Moawia Gameraddin [3] | Abdalmoneim A. M

Share this Article

Downloads: 104

Research Paper, Medicine Science, Sudan, Volume 4 Issue 12, December 2015

Pages: 2110 - 2113

Calculation of Radiation Dose Received by Patients during Cardiac Interventional Procedure

Abdoelrahman Hassan A. B [15] | M. E. M. Gar-elnabi [4] | Eitidal H. Khalafalla | F. I. Habani

Share this Article
Top