International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 125 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper | Medicine Science | Egypt | Volume 4 Issue 12, December 2015


Effect of Cantileverd Bar Length on Strain Around Two and Four-Implants Supporting A Mandibular Over-Denture

Mohamed Sherine El Attar | Faten Salah El Din | Jailan Salem


Abstract: Statement of problem There is little information as to how the cantilevered bar length affect the strain around two and four implants supporting a mandibular over denture Purpose measure the effect of cantilevered bar length on strain produced around two-implant and four-implant supporting a mandibular over denture, and evaluating the amount of stress reaching the supporting structures. Materials and methods Two root-form implants were placed bilaterally in the canine region of an edentulous acrylic mandibular model (group A). Also four root-form implants were placed in the canine & bicuspid region of another edentulous acrylic mandibular model (group B). The implants on each model were connected with a resilient bar/clip attachment with the following lengths of cantilevered bar length 11mm, 9mm and 7mm. Four linear strain gauges were bonded to the acrylic resin at the mesial & distal surface of each implant. Each gauge was wired separately into a 1/4 Wheatstone bridge of a multichannel digital bridge amplifier. Strains were measured on each model. Strain measurements were performed under central loading using a loading device. Results when using two or four implants, the 11mm cantilevered bar length generated the highest peri-implant strain values, while the 7mm cantilever length recorded the lowest under central loading conditions. A positive correlation between the cantilever length and the peri-implant strain was found. The same effect was found on the supporting structures. Conclusion The 7mm cantilevered bar with clips placed on the cantilevers was recommended when 2 or 4 implants were used to support mandibular over dentures as it demonstrated the lowest magnitude of strains with no significant differences between peri-implant sites


Keywords: Cantilever, bar, strain, implant, over denture


Edition: Volume 4 Issue 12, December 2015,


Pages: 27 - 33


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Mohamed Sherine El Attar, Faten Salah El Din, Jailan Salem, "Effect of Cantileverd Bar Length on Strain Around Two and Four-Implants Supporting A Mandibular Over-Denture", International Journal of Science and Research (IJSR), Volume 4 Issue 12, December 2015, pp. 27-33, https://www.ijsr.net/get_abstract.php?paper_id=NOV151749

Similar Articles with Keyword 'bar'

Downloads: 2 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Review Papers, Medicine Science, Malaysia, Volume 11 Issue 2, February 2022

Pages: 1036 - 1036

Advances in the Study of Multiple Sclerosis and the Immune Microenvironment

Yuanyuan Zou [3] | Qinri Zheng [2]

Share this Article

Downloads: 44

Research Paper, Medicine Science, Iraq, Volume 6 Issue 7, July 2017

Pages: 1515 - 1520

Baseline Needs Assessment for Breast Cancer Awareness and Management among Paramedical Health Care Providers in Iraq

Nada A.S. Alwan [2] | Wafa' M. Alattar | Nawar Al Mallah [2] | Thamira K. Hassoun

Share this Article
Top