International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 142 | Weekly Hits: ⮙1 | Monthly Hits: ⮙2

Research Paper | Radiological Sciences | India | Volume 8 Issue 7, July 2019


Commissioning of 6 MV UNIQUE Performance Medical Accelerator: Dosimetric Evaluation and TPS Validation using AAPM TG -119 and IAEA CIRS Test Cases

Venugopal Sundaram | Sothing Vashum


Abstract: To test the overall accuracy and quality of IMRT and VMAT plans following AAPM TG119 and IAEA test recommendation and to validate the test plans for clinical implementation by comparing the calculated and measured doses. The recommendations in AAPM TG119 include planning objectives, dose delivery and measurement conditions for different clinically relevant and common test cases of IMRT & VMAT. IAEA end-to-end audit performed on CIRS phantom to test the overall accuracy of all treatment modalities. The phantom was made to undergo similar processes to a patients undergoing radiotherapy. For cases planned with TG119 recommendation the gamma analysis and point dose measurements were performed. The mean dose observed for IMRT in point dose measurement found to be -0.08 % and Confidence Limit obtained were: a) point dose measurements 0.56 % b) measured gamma analysis is 4.66 c) Portal dosimetry (PD) gamma analyses is 0.12. VMAT plans shows mean dose variation for point dose measurement is 0.30 % and Confidence Limit obtained were: a) point dose measurements 1.15 b) measured gamma analysis is 3.46 (1 ARC) & 3.35 (2 ARC) c) gamma analysis is 0.85 (1 ARC) & 1.36 (2 ARC). IAEA test shows maximum point dose variation 2.149 % in VMAT.


Keywords: Confidence Limit, Point dose measurement, Gamma analysis


Edition: Volume 8 Issue 7, July 2019,


Pages: 1171 - 1177


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Venugopal Sundaram, Sothing Vashum, "Commissioning of 6 MV UNIQUE Performance Medical Accelerator: Dosimetric Evaluation and TPS Validation using AAPM TG -119 and IAEA CIRS Test Cases", International Journal of Science and Research (IJSR), Volume 8 Issue 7, July 2019, pp. 1171-1177, https://www.ijsr.net/get_abstract.php?paper_id=ART20199808

Similar Articles with Keyword 'Confidence'

Downloads: 115

Case Studies, Radiological Sciences, Saudi Arabia, Volume 5 Issue 4, April 2016

Pages: 1146 - 1149

Cardiac CT of a Criss-Cross Heart: A Case Report

Amr M. Ajlan MD [2]

Share this Article

Downloads: 123

Research Paper, Radiological Sciences, Saudi Arabia, Volume 5 Issue 1, January 2016

Pages: 1809 - 1815

Normal Tracheal Measurements in the Saudi Population Using Computed Tomography

Mai Banjar MD | Amr Ajlan MD | Talal Al-Khatib MD | Mohamed Amine Haireche | Ghofran Ageely MD | Doaa Saggat | Ghaith Shukri | Hani Marzouki MD

Share this Article
Top