International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 130

Research Paper | Dental Science | Iraq | Volume 7 Issue 1, January 2018


Accuracy of Polyvinyl Siloxane Impression Material with Different Inter Implant Angulation

Yagthan M. Haider | Hasnahbinti Hashim | Mani Maran Ratnam | Norziha Yahaya


Abstract: The suitability of a recommended material for implant impressions and the effects of implant angulation on the accuracy of the working cast remain debatable. Thus, evaluating the effect of impression materials with different implant angulations on the accuracy of impression is important (Cehreli et al. , 2006). Four block shaped acrylic master models were fabricated with two implant analogs in each the first was placed at 0 angulation (reference implant) while the second was at 0, 5, 10, and 15 respectively. Sixty-four impressions were taken, 16 impressions for each of the four master casts, eight of them made using Aquasil impression material and the other eight impressions with Virtual impression material. IBM SPSS v.22 (SPSS Inc, Chicago) was demonstrated. according to the results material elasticity and inter-implant angulation had a combined effect on the accuracy of the implant impression (p =0.03). The inter-implant angulations were significantly associated with the impression accuracy (p= 0.027) regardless of the elasticity of the material. Post-hoc analysis using Tamhanes procedure showed a significant difference between angulation pairs of 0 - 10 and 0 - 15. The study demonstrated that the interaction between PVS impression materials of different elasticity (Virtual and Aquasil medium body) and the inter implant angulation of the analogs placed divergently produced a significant adverse effect on the impression accuracy. Regardless of material elasticity, the angulation of the implant analogs also adversely affects the impression accuracy


Keywords: Dental Implants, inter-implant angulation, elasticity, Vinyl Polysiloxane, Dimensional Measurement Accuracy


Edition: Volume 7 Issue 1, January 2018,


Pages: 969 - 973


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Yagthan M. Haider, Hasnahbinti Hashim, Mani Maran Ratnam, Norziha Yahaya, "Accuracy of Polyvinyl Siloxane Impression Material with Different Inter Implant Angulation", International Journal of Science and Research (IJSR), Volume 7 Issue 1, January 2018, pp. 969-973, https://www.ijsr.net/get_abstract.php?paper_id=ART20179039

Similar Articles with Keyword 'Dental Implants'

Downloads: 1 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Review Papers, Dental Science, India, Volume 11 Issue 7, July 2022

Pages: 1606 - 1612

Compatibility and Safety of MRI with Dental Implant - A Dilemma to Solve

Bhawana [10] | Supriya Jain | Chandergupt | Arundeep Kaur Lamba | Farrukh Faraz | Shruti Tandon

Share this Article

Downloads: 35

Research Paper, Dental Science, Brazil, Volume 10 Issue 2, February 2021

Pages: 1599 - 1607

Digital Comparative Method for Analysis of Body Remodeling and Neoformation: Case Report

Norival F. Souza Jr | Helton Panisson [3] | Guenther Schuldt Filho [4]

Share this Article
Top