International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 150

Research Paper | Dental Science | Egypt | Volume 5 Issue 10, October 2016


Evaluation of Accuracy of Immediate Dental Implant Placement Using Stereolithographic Surgical Stent

Abdelkarim M. Kamar | Nagy El-Prince Hassan | Hala R. Ragab


Abstract: Background The success of implant therapy depends primarily on appropriate treatment planning and properly performed implant placement surgery, this can be achieved by means of surgical guide stents which are designed in conventional methods or by stereolithography. The aim of the study Evaluation of the accuracy of immediate implant placement using stereolithographic surgical stent. Materials and methods Ten implants were placed in patients having fresh extracted socket, implants were placed using stereolithographical design of surgical stent then measuring the deviation between the planned implant position before the surgery and the actual position of the placed implant after surgical procedure using cone beam computed tomography CBCT. Clinical assessment was done including implant primary stability, implant mobility, periimplant probing depth, sulcus bleeding index and bleeding on probing. Also radiographical evaluation was done to measure bone density and marginal bone height around implants. Assessment of implant distance to the maxillary sinus was also done by measuring the distance between implant planned and maxillary sinus by preoperative CBCT planning then measuring the actual placed implant distance to the maxillary sinus by postoperative CBCT. Results Pain and edema decreased gradually throughout the follow up period. All implants showed both clinical and radiographical success. Stereolithographic stent shows minimal deviation between planned and actual placed implants. Conclusions Immediate implant placement is a successful treatment option for restoring hopeless tooth, The guided surgery is a new modality for safe and easy implant insertion and using a stereolithographic stent for immediate implant placement is a good tool for that with an excellent outcomes.


Keywords: Immediate implant, stereolithographic stent


Edition: Volume 5 Issue 10, October 2016,


Pages: 716 - 723


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Abdelkarim M. Kamar, Nagy El-Prince Hassan, Hala R. Ragab, "Evaluation of Accuracy of Immediate Dental Implant Placement Using Stereolithographic Surgical Stent", International Journal of Science and Research (IJSR), Volume 5 Issue 10, October 2016, pp. 716-723, https://www.ijsr.net/get_abstract.php?paper_id=ART20162213

Similar Articles with Keyword 'Immediate implant'

Downloads: 2 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Dental Science, Bulgaria, Volume 12 Issue 1, January 2023

Pages: 1136 - 1139

Analysis of the Applying Implants Methods in Conditions of Subantral Deficiency, Compared to the Available Subantral Bone in Cases with Completed Maxillary Sinus Floor Augmentation with Lateral Approach

Desislava Stoyanova [5] | Stefan Peev [16] | Tihomir Georgiev [3] | Georgi Papanchev [2]

Share this Article

Downloads: 80

Review Papers, Dental Science, India, Volume 9 Issue 9, September 2020

Pages: 1461 - 1465

Guided Bone Regeneration in Immediate Dental Implants - Review

Dr. Koyel Bhowal | Dr. Samiran Ghosh

Share this Article
Top