International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 112

Research Paper | Electrical Engineering | India | Volume 3 Issue 9, September 2014


Suppression of Secondary Arc Current in Extra High Voltage 765 KV Transmission Line of 4 Bus System

Avinash Sharma [2] | Arti Bhandakkar [3]


Abstract: The effectiveness of single-pole auto reclosure (SPAR) in maintaining power system stability is largely determined by the speed with which secondary arc extinction, and hence auto reclosure, can be achieved. In this work there is approach to measure the suppression of secondary arc current by Neutral reactor (shunt reactor) which is applied widely in many countries. In this paper the different results of healthy 4 Bus system, faulted system, Breakers operation without Neutral reactor are compared with the Neutral reactor and Simulation studies were carried out in the MATLAB simulation environment to observe the secondary arc current suppression is achieved by the Neutral reactor is better as compared to without neutral reactor. For the simulation purpose, the model of two-machine 4-bus system with healthy operation, faulted system operation, breaker operation without Neutral Reactor and with Neutral Reactor operation is developed in MATLAB/SIMULINK using Simpower System (SPS) blockset.


Keywords: Neutral Reactor shunt reactor, Secondary arc, single-phase grounding fault, Test system model, MATLAB/SIMULINK,


Edition: Volume 3 Issue 9, September 2014,


Pages: 2095 - 2100


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Avinash Sharma, Arti Bhandakkar, "Suppression of Secondary Arc Current in Extra High Voltage 765 KV Transmission Line of 4 Bus System", International Journal of Science and Research (IJSR), Volume 3 Issue 9, September 2014, pp. 2095-2100, https://www.ijsr.net/get_abstract.php?paper_id=21091403

Similar Articles with Keyword 'Neutral'

Downloads: 100

Research Paper, Electrical Engineering, India, Volume 9 Issue 7, July 2020

Pages: 461 - 465

Two-Leg VSC- as DSTATCOM Based on Carrier less Hysteresis Current Control Algorithm for Power Quality Improvement

Vikas Kumar Sharma [2] | Asha Kumari [2] | Pawan Raj Koodi | Rahul Yadav [2]

Share this Article

Downloads: 108

M.Tech / M.E / PhD Thesis, Electrical Engineering, India, Volume 3 Issue 9, September 2014

Pages: 2117 - 2121

A Novel Method to Improve Power Quality Using Fuzzy Logic Controller and Reducing Harmonics Using Filters

K. Vijaya Kumar [4]

Share this Article
Top