International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 120

Research Paper | Mechanical Engineering | India | Volume 3 Issue 7, July 2014


Programming of HC900 Controller based Speed Control System for D.C. Motor

L. B. Raut | P. K.Parase | Suraj Jagtap


Abstract: In process control industries the concept of multiple input, multiple output control systems is the key work now days. The control variables are analog nature as well as digital nature. To control these mixed type of variables hybrid controller is popularly used. The hybrid controller is a basic platform of SCADA. In which monitoring recording and display of variables with respect to time, animation of various control components is possible. Therefore, a project is taken up to establish a speed control system of the motor by controlling the power input from a dedicated motor controller through discrete controller as a process. Hybrid controller Make of Honeywell Model HC-900 having 8-Analog I/P, (4-20mA) Analog O/P, 16-Digital I/P, 16-Digital O/P, 8-Control loop; as a controller and Honeywell Plants cape is taken as SCADA software. In this phase all these control components shall be properly arranged on a table top setup. The HMI (Human Machine Interface) shall be used through HC 900 to set the desired speed. The output of HMI is 4-20 mA this will act as one of the analog input of HC900. The tachometer signal (4 - 20 mA) shall provide the feedback input, and accordingly the output i. e.4-20 mA shall drive the DC motor controller through HC900 Controller. After motor shall output the rpm, depending upon the load to the motor as it is coupled to eddy current dynamometer. Varying the input 4-20 mA of Eddy current dynamometer shall vary the load on the motor. A fairly large amount of experimentation shall be carried out on motor coupled with dynamometer and tachometer. The family of operating curves that is speed (mA) as Abscissa, motor controller input (4-20mA) as ordinate and various torque lines. The linearization of this figure shall evaluate the block diagram of the plant. Applying appropriate analysis methods HC900 shall be configured along


Keywords: HC 900, SCADA, HMI, PID FUNCTION BLOCK, PROGRAMMING


Edition: Volume 3 Issue 7, July 2014,


Pages: 2310 - 2317


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

L. B. Raut, P. K.Parase, Suraj Jagtap, "Programming of HC900 Controller based Speed Control System for D.C. Motor", International Journal of Science and Research (IJSR), Volume 3 Issue 7, July 2014, pp. 2310-2317, https://www.ijsr.net/get_abstract.php?paper_id=2015115

Similar Articles with Keyword 'HMI'

Downloads: 109 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Mechanical Engineering, India, Volume 4 Issue 10, October 2015

Pages: 1709 - 1711

Design, Manufacture and Test of a Solar Powered Audible Bird Scarer and Study of Sound Ranges Used in it

Vikrant Rajesh Suryawanshi

Share this Article

Downloads: 130 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Mechanical Engineering, India, Volume 7 Issue 2, February 2018

Pages: 1179 - 1182

Experimentation on Double Pipe Heat Exchanger Using Water and Nanofluid

J. Emeema | C. Lakshmi Sindhuja | K. Laxman [2]

Share this Article
Top