International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Fully Refereed | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064


Downloads: 129

Research Paper | Civil Engineering | India | Volume 3 Issue 7, July 2014


Structural Configuration Optimization of a Multistorey Building by Optimum Positioning of Shear Wall

M. Tamim.A


Abstract: The shear wall is a structural element which is used to resist earthquake forces. These wall will consumptives shear forces & will prevent changing location-position of construction & consequently destruction. On other hand, shear wall arrangement must be absolutely accurate, if not, we will find negative effect instead. For example if the shear walls make an increase distance between mass centre and hardness centre, we cannot expect a good tensional behavior from the structure. In case of mass centre and hardness centre coincide with each other, at that time the distance of shear wall from the mass centre also plays an important role in the shear contribution of the shear wall. The bending moment, shear force, torsion, axial force contribution by rest of the structural element and the ultimate design of all the structural components also affected by that. A study has been carried out to determine the optimum Structural configuration of a multistory building by changing the shear wall locations radically. Four different cases of shear wall position for a 10 storey residential building with keeping zero eccentricity between mass centre and hardness centre have been analyzed and designed as a space frame system by computer application software, subjected to lateral and gravity loading in accordance with IS provisions.


Keywords: Shear walls, Lateral loading, Zero eccentricity, Stresses, Design configuration


Edition: Volume 3 Issue 7, July 2014,


Pages: 77 - 81


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

M. Tamim.A, "Structural Configuration Optimization of a Multistorey Building by Optimum Positioning of Shear Wall", International Journal of Science and Research (IJSR), Volume 3 Issue 7, July 2014, pp. 77-81, https://www.ijsr.net/get_abstract.php?paper_id=14061402

Similar Articles with Keyword 'Shear walls'

Downloads: 1 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Civil Engineering, India, Volume 11 Issue 5, May 2022

Pages: 337 - 341

A Review on High Rise Building with Shear Wall under Seismic Loading

C. R. Urkude | P. G. Atole | G. P. Chavan | R. B. Pawar | D. W. Gawatre

Share this Article

Downloads: 8 | Weekly Hits: ⮙1 | Monthly Hits: ⮙2

Research Paper, Civil Engineering, India, Volume 10 Issue 7, July 2021

Pages: 213 - 223

Effect of Shear Wall in Seismic Performance of High-Rise Irregular RC Framed Building

Yagya Raj Khatri | Dr. Prasenjit Saha

Share this Article
Top