Abstract: Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine
International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Open Access | Fully Refereed | Peer Reviewed

ISSN: 2319-7064

Downloads: 105

Survey Paper | Radiological Sciences | Egypt | Volume 4 Issue 4, April 2015

Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine

Allehyani S. H., Taha M.T., Bahashwan Y. M.

The aim of this study was to analyze factors influencing the quality assurance of superficial radiotherapy X-ray machine such as dose output reproducibility, linearity, kV accuracy, time accuracy. Moreover the entrance skin dose for hand, face and nose using Perspex phantom was measured. We measured these factors and entrance skin doses using Unidose master connected with 0.2 cc soft X-Ray Chamber type 23342, which was placed above a Perspex phantom inside the chosen field size of used applicator on the couch. The reproducibility of dose output was 0.17 %, the kilo voltage accuracy percentage and time accuracy percentage were ranged from.38 to 0.87 % and -0.96 to 3.4 % respectively. Linearity of radiotherapy X-ray machine was 0.02 which lower than the tolerance limit of the American Association of physicist in Medicine reference value, the limit specified in the academic literature and international publications. The relative error for entrance skin dose equals 3 %. The entrance skin doses for face, nose and hand were 56.68 0.307, 241.2 2.15 and 60.52 0.104 mGy respectively. The tests for the quality assurance of superficial radiotherapy X-ray machine was compared and assessed with the international tolerance.

Keywords: Quality Assurance, Unidose, 02 cc Soft X-Ray Chamber

Edition: Volume 4 Issue 4, April 2015

Pages: 1316 - 1319

Share this Article

How to Cite this Article?

Allehyani S. H., Taha M.T., Bahashwan Y. M., "Study the Factors Affecting the Quality Assurance of Superficial RadiotherapyX-RayMachine", International Journal of Science and Research (IJSR), https://www.ijsr.net/search_index_results_paperid.php?id=SUB153341, Volume 4 Issue 4, April 2015, 1316 - 1319

Enter Your Email Address


Similar Articles with Keyword 'Quality Assurance'

Downloads: 127

Survey Paper, Radiological Sciences, Egypt, Volume 4 Issue 3, March 2015

Pages: 372 - 375

Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter

Taha.M.T

Share this Article

Downloads: 132

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 1, January 2015

Pages: 1875 - 1878

Evaluation of Diagnostic Radiology Department in Term of Quality Control (QC) of X-Ray Units at Khartoum State Hospitals

H.A.Ismail, O.A.Ali, M.A.Omer, M.E.Garelnabi, N.S.Mustafa

Share this Article

Similar Articles with Keyword 'Quality'

Downloads: 111

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 7, July 2015

Pages: 2383 - 2386

Appraisal of Radiation Dose Received in Abdominal Computed Tomography Patients

Yousif Mohamed Y. Abdallah, Magbool A. H. Salih

Share this Article

Downloads: 114

Research Paper, Radiological Sciences, Saudi Arabia, Volume 4 Issue 2, February 2015

Pages: 2117 - 2121

Assessment of Gamma Camera SPECT Resolution using Developed Quality Control Phantom

Mohamed E. M. Gar-elnabi, Wadah M. Ali, Mohammed A. Ali Omer, Ghada A. Edam

Share this Article

Similar Articles with Keyword 'Assurance'

Downloads: 127

Survey Paper, Radiological Sciences, Egypt, Volume 4 Issue 3, March 2015

Pages: 372 - 375

Study the Quality Assurance of Conventional X-Ray Machine using Non-Invasive KV Meter

Taha.M.T

Share this Article

Downloads: 132

Research Paper, Radiological Sciences, Sudan, Volume 4 Issue 1, January 2015

Pages: 1875 - 1878

Evaluation of Diagnostic Radiology Department in Term of Quality Control (QC) of X-Ray Units at Khartoum State Hospitals

H.A.Ismail, O.A.Ali, M.A.Omer, M.E.Garelnabi, N.S.Mustafa

Share this Article