International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Since Year 2012 | Open Access | Double Blind Reviewed

ISSN: 2319-7064


Downloads: 2 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper | Orthopaedic Surgery | India | Volume 11 Issue 1, January 2022


Volar Locking Plate versus External Fixation for Displaced Intra-Articular Distal Radius Fractures: A Prospective Randomized Comparative Study of the Radiological Parameters and Functional Outcomes

Dr. Partha Pratim Chakraborty | Dr. Ayon Ghosh | Dr. Anindya Maiti | Dr. Arumoy Bhuimali | Dr. Aniruddha Mandal | Dr. Kanchan Gurung


Abstract: Background: The objective of the study was to compare the efficacy of external fixation and volar plating on the Radiological (Radial length, Radial inclination and volar tilt) and functional parameter (QUICK DASH score) of completely articular (AO 23 C1, 23 C2, 23 C3) distal end radius fractures. Materials and methods: This prospective randomized study comprised 27 patients treated with external fixation and 33 patients treated with volar locking plates. The patients were followed up at 6 weeks, 12 weeks and 6 months after surgery. At the time of follow up the radiological parameters and Q-DASH scores were assessed. Results: At 6 months after surgery, we observed volar locking plate patients showed better results than external fixator patients with respect to both radiological parameters and functional status. Both volar tilt (External fixation, 11.37 ? 1.47; Volar plate, 12.12 ? 1.34) and radial inclination (External fixation, 22.26 ? 1.63; Volar plate, 23.27 ? 0.72) showed statistically significant difference in-betweenboth the groups. Although radial length was not statistically significant. Again QUICK Dash score (External fixation, 9.71 ? 3.55; volar plating, 6.80 ? 0.46) also showed statistically significant difference. Conclusion: Volar locking plate is superior in comparison to external fixation in cases of completely intra articular distal radius fractures.


Keywords: Distal radius fracture, JESS, K-Wire, Volar locking plate


Edition: Volume 11 Issue 1, January 2022,


Pages: 1536 - 1542


How to Download this Article?

You Need to Register Your Email Address Before You Can Download the Article PDF


How to Cite this Article?

Dr. Partha Pratim Chakraborty, Dr. Ayon Ghosh, Dr. Anindya Maiti, Dr. Arumoy Bhuimali, Dr. Aniruddha Mandal, Dr. Kanchan Gurung, "Volar Locking Plate versus External Fixation for Displaced Intra-Articular Distal Radius Fractures: A Prospective Randomized Comparative Study of the Radiological Parameters and Functional Outcomes", International Journal of Science and Research (IJSR), Volume 11 Issue 1, January 2022, pp. 1536-1542, https://www.ijsr.net/get_abstract.php?paper_id=SR22118212902

Similar Articles with Keyword 'Distal radius fracture'

Downloads: 2

Research Paper, Orthopaedic Surgery, India, Volume 10 Issue 6, June 2021

Pages: 1512 - 1519

Clinicoradiological Outcome of Intra Articular Distal End Radius Fracture with Volar Locking Plates

Shreekar Arte | Amit Dave [2]

Share this Article

Downloads: 34 | Weekly Hits: ⮙1 | Monthly Hits: ⮙1

Research Paper, Orthopaedic Surgery, India, Volume 10 Issue 2, February 2021

Pages: 1462 - 1466

Study of the Functional and Radiological Outcome of Surgical Management of Unstable Extra - Articular Fracture of Distal End of Radius by Closed Reduction and Internal Fixation with K Wire

Dr. Amit Dave

Share this Article
Top