International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Call for Papers | Open Access | Double Blind Peer Reviewed

ISSN: 2319-7064




Downloads: 59 | Views: 70

Research Paper | Electrical & Electronics Engineering | India | Volume 9 Issue 12, December 2020


Variance Index of Three Phase Instantaneous Power based Fault during Power Swing

Prasanth Gullinka | Kumarraja.A [4]


Abstract: Distance relays are intended to operate reliably and secured manner, and are rigorously complied with to eschew mal-operation during stressed condition. To eschew these conditions, power swing blocking functions (PSB) is included in the distance relay design. But, any kind of fault is commencing during swing, the PSB function should unblock it and provides trip signal to the circuit breakers (CB). Unsymmetrical fault cases were facilely unblocked, except in the case of symmetrical fault during power swing condition is a difficult task for relay unblocking due to balanced phenomenon. Variance indexes of three phase instantaneous power signal (VITPIP) predicated symmetrical fault detection during power swing is presented in this paper. The method utilizes quantified three-phase voltage and current signals from relay end. Extraction of high frequency components of three-phase instantaneous power signals utilizing DWT. Subsequently, variance index is estimated for the details coefficients of power signals avails to discriminate the symmetrical fault from swing event. To validate the accuracy of the proposed technique, a 400 kV, 50 Hz single machine illimitable bus system is considered and simulated in the MATLAB / SIMULINK platform. Different critical cases such as fault inception time, slip frequency, fault resistance and fault location were considered for the simulation. The results, it illustrates that the proposed method is more efficient.


Keywords: Distance relay, Transmission lines, Three-phase instantaneous power signal, Symmetrical fault, Power swing, Wavelet transform, Variance estimation


Edition: Volume 9 Issue 12, December 2020,


Pages: 1057 - 1060


How to Download this Article?

Type Your Email Address below to Download the Article PDF


How to Cite this Article?

Prasanth Gullinka, Kumarraja.A, "Variance Index of Three Phase Instantaneous Power based Fault during Power Swing", International Journal of Science and Research (IJSR), Volume 9 Issue 12, December 2020, pp. 1057-1060, https://www.ijsr.net/get_abstract.php?paper_id=SR201218132504



Similar Articles with Keyword 'relay'

Downloads: 2 | Weekly Hits: ⮙2 | Monthly Hits: ⮙2

Research Paper, Electrical & Electronics Engineering, Sudan, Volume 11 Issue 11, November 2022

Pages: 1404 - 1408

Transmission Line Protection Using Artificial Neural Networks

Helal Qahtan | Ekram Osman | Ebrahim Al-hamidi

Share this Article

Downloads: 51 | Weekly Hits: ⮙1 | Monthly Hits: ⮙2

Review Papers, Electrical & Electronics Engineering, Bangladesh, Volume 10 Issue 2, February 2021

Pages: 1380 - 1391

A Review of Digital FIR Filter Design in Communication Systems

Kamal Hossain | Roni Ahmed | Md. Asadul Haque | Muahmmad Towfiqur Rahman

Share this Article



Top