Research Paper | Chemistry | Iraq | Volume 3 Issue 10, October 2014


New design and Modulating of Spectroinc 20 to the Home- Made Semi-Automated Chemiluminescence Flow Injection System and Determination of Hydrogen Peroxide in Pharmaceutical Formulations

K. H. Al Sowdani | M. Abdulkadhim. H


Abstract: A novel design has been constructing and modulating of Spectroinc 20 to measure the chemiluminescence by the home- made semi-automated flow injection system. The proposed method was direct, simple and rapid for determining Hydrogen peroxide in the rang 3.3-106 gml-1 based on chemiluminescence by oxidation with luminol in aqueous sodium carbonate (PH 10). The detection limit (3noice) of 1.6 gml-1, the r. s. d % for fife determination of 26.5 gml-1 Hydrogen peroxide was 0.35 %. . The applicability of the method was demonstrated by the determination of Hydrogen peroxide in pharmaceutical formulations.


Keywords: Spectrinc 20, Chemiluminescence determination, Flow injection, Luminol, Hydrogen peroxide, pharmaceutical formulations


Edition: Volume 3 Issue 10, October 2014,


Pages: 1920 - 1925

New design and Modulating of Spectroinc 20 to the Home- Made Semi-Automated Chemiluminescence Flow Injection System and Determination of Hydrogen Peroxide in Pharmaceutical Formulations


How to Cite this Article?

K. H. Al Sowdani, M. Abdulkadhim. H, "New design and Modulating of Spectroinc 20 to the Home- Made Semi-Automated Chemiluminescence Flow Injection System and Determination of Hydrogen Peroxide in Pharmaceutical Formulations", International Journal of Science and Research (IJSR), https://www.ijsr.net/get_abstract.php?paper_id=OCT14519, Volume 3 Issue 10, October 2014, 1920 - 1925, #ijsrnet

How to Share this Article?

Enter Your Email Address




Similar Articles with Keyword 'Flow injection'

Downloads: 108

Research Paper, Chemistry, Iraq, Volume 6 Issue 12, December 2017

Pages: 1131 - 1138

Normal Flow and Stopped Flow Injection Spectrophotometric Determination of Quercetin Dihydrate Dietary Supplements

Sadeem Subhi Abed [3] | Hinda Ali Mahmood

Share this Article

Downloads: 124

Research Paper, Chemistry, Iraq, Volume 6 Issue 8, August 2017

Pages: 1505 - 1512

An Alternative Method for Determination of Chloramphenicol in Pharmaceutical Formulation by Laser Fluorimeter Analyser

Mohammad K. Hammood [2] | Maryam A. Khalaf

Share this Article


Top