Downloads: 94 | Views: 104
Research Paper | Chemistry | Egypt | Volume 3 Issue 11, November 2014
Chronoamperometric Determination of Sulphite Using Gold- Printed Electrode
Abstract: A chronoamperometric method for the determination of sulphite ions has been developed using disposable, screen-printed gold electrodes in presence of some mediators. The used mediators include: potassium hexacyanoferrate (III), hydroxymethylferrocene, 4- (methylamino) phenol sulphate. Calibration curves exhibit a linear relationship between the electrode response and the sulphite concentration over the range from 100 M to 3.00 mM. The correlation coefficients for calibration curve was equal to 0.992. The obtained limit of detection (LOD) was 30 M. The relative standard deviations were equal to or better than 6.96 % (n=5). The interferences of various ions were studied. The used sensors are successfully applied for the determination of sulphite in tap water and agriculture drain water. It was found that the used screen-printed electrodes have its initial response after storage in dry state at room temperature up to eight months.
Keywords: screen-printed electrodes, Chronoamperometry, Sulphite, Mediators, electroanalysis
Edition: Volume 3 Issue 11, November 2014,
Pages: 2278 - 2281
Similar Articles with Keyword 'electrodes'
Downloads: 95
Research Paper, Chemistry, Egypt, Volume 3 Issue 12, December 2014
Pages: 1406 - 1409Electrochemical Sensor Based On Carbon Printed Electrode
M. Khodari [5] | A.A.H. Basry | G. Mersal
Downloads: 103
Research Paper, Chemistry, India, Volume 4 Issue 5, May 2015
Pages: 1017 - 1019Potentiometric Study of Hydroxamic Acids in Non- Aqueous Media
Piyush Kumar Thakur [3] | Sandhya Patre [2]