Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Abdul Jabbar Khan, Amjadullah Khattak

This paper presents that to check the transient response of synchronous generators various tests are performed. Short circuit test is basically for the purpose to find the values of time constants & reactances of synchronous generator. To check the validity of these time constants & reactances achieved after the test. A synchronous generator rated 40 MVA with direct connected exciter rated 200 KW installed at Warsak Dam Pakistan is modeled with its various parameters in matlab simulink and its short circuit test is performed. First the theoretical response during short circuit test of each phase of synchronous generator is described, then the matlab simulink response is compared with theoretical response. The results clearly show that the theoretical response completely matches the matlab response. From the results it is deduced that the values of reactances and time constants calculated after a factory short circuit test were correct.

Keywords: Synchronous generator SG, Transient, Short circuit test, Reactance, Time constant

Edition: Volume 5 Issue 1, January 2016

Pages: 1901 - 1906


How to Cite this Article?

Abdul Jabbar Khan, Amjadullah Khattak, "Verification of Short Circuit Test Results of Salient Poles Synchronous Generator", International Journal of Science and Research (IJSR), https://www.ijsr.net/search_index_results_paperid.php?id=NOV153202, Volume 5 Issue 1, January 2016, 1901 - 1906

11 PDF Views | 15 PDF Downloads

Download Article PDF



Similar Articles with Keyword 'Transient'

Research Paper, Power Engineering, India, Volume 4 Issue 4, April 2015

Pages: 1186 - 1189

Transient Stability Analysis of SMIB in Power System Using Artificial Neural Network

Sanoj Kumar, Girish Dalal

Share this article

Research Paper, Power Engineering, Pakistan, Volume 5 Issue 1, January 2016

Pages: 1901 - 1906

Verification of Short Circuit Test Results of Salient Poles Synchronous Generator

Abdul Jabbar Khan, Amjadullah Khattak

Share this article

Research Paper, Power Engineering, India, Volume 3 Issue 4, April 2014

Pages: 385 - 388

Enhancement of Transient Stability in a 9 Bus System using Matrix Converter Based UPFC

Selvamani Prabaharan.M, Lakshmanan.P

Share this article

Case Studies, Power Engineering, India, Volume 5 Issue 5, May 2016

Pages: 2218 - 2222

Study of Switching Transients on EHV AC Transmission Line

Sudhir Kumar Singh

Share this article

Top