Calculation of Radiation Dose Received by Patients during Cardiac Interventional Procedure
International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
www.ijsr.net | Open Access | Fully Refereed | Peer Reviewed International Journal

ISSN: 2319-7064

Downloads: 104 | Weekly Hits: ⮙3 | Monthly Hits: ⮙10

Research Paper | Medicine Science | Sudan | Volume 4 Issue 12, December 2015

Calculation of Radiation Dose Received by Patients during Cardiac Interventional Procedure

Abdoelrahman Hassan A. B, M. E. M. Gar-elnabi, Eitidal H. Khalafalla, F. I. Habani

The process of interventional procedure can be associated with multilevel of radiation doses, the current study intends to measure patient dose and estimate the radiation dose received for patient during interventional cardiology (IC) procedures. In order to match the acceptable level, A 206 patients underwent IC procedure and the radiation dose were measured in Khartoum state hospitals, Sudan, in four types of (IC) procedures which are (CA, PCI, PTMC and pacemaker) the number patients for each procedure was 145, 39, 4 and 18 respectively. The mean age of patients was 59.914.1 which ranged from 3 to 100 years. The mean value of tube parameter was 78.211.4KVp, (ranged from 50 to 109 Kvp), 7.1 0.72 mAs (ranged from 3 to 10.2 mAs). The mean time of fluoroscopy exposure that was used during these procedure was 6.97.1 mint. Dosimetric quantity, called KERMA Area Product (KAP), and uoroscopy time were registered during four selected procedures. For CA, PCI, PTMC and pacemaker the mean and median KAP values demonstrated as higher and lower values were found to be (63.69, 52 Gy.cm2) (18.78, 15.5 Gy.cm2) for PCI and pacemaker respectively. The higher mean and median uoroscopy time in minutes (11.43, 9.70) as registered for PCI procedure was reported in this study which may considered relatively higher value than reported in the literature.

Keywords: pacemaker, interventional radiology, radiation dose and KAP

Edition: Volume 4 Issue 12, December 2015

Pages: 2110 - 2113

Share this Article

How to Cite this Article?

Abdoelrahman Hassan A. B, M. E. M. Gar-elnabi, Eitidal H. Khalafalla, F. I. Habani, "Calculation of Radiation Dose Received by Patients during Cardiac Interventional Procedure", International Journal of Science and Research (IJSR), https://www.ijsr.net/search_index_results_paperid.php?id=NOV152392, Volume 4 Issue 12, December 2015, 2110 - 2113

Enter Your Registered Email Address





Similar Articles with Keyword 'pacemaker'

Downloads: 98 | Monthly Hits: ⮙4

Research Paper, Medicine Science, Poland, Volume 4 Issue 12, December 2015

Pages: 1140 - 1144

Functional Disorders of Heart Stimulating Systems in Patients Treated with Radiation Therapy ? Own Experiences

Ewa Zikowska, Tomasz Winiewski, Mieszko Biaas

Share this Article

Downloads: 99 | Weekly Hits: ⮙1 | Monthly Hits: ⮙11

Research Paper, Medicine Science, India, Volume 4 Issue 12, December 2015

Pages: 2091 - 2095

Outcome Analysis of Cardiac Resynchronisation of Moderate to Severe Heart Failure in Relation to Blood Pressure Exercise Tolerance and Electrocardiography Changes

Brajendra Kumar, Raj Kumar

Share this Article

Downloads: 104 | Weekly Hits: ⮙3 | Monthly Hits: ⮙10

Research Paper, Medicine Science, Sudan, Volume 4 Issue 12, December 2015

Pages: 2110 - 2113

Calculation of Radiation Dose Received by Patients during Cardiac Interventional Procedure

Abdoelrahman Hassan A. B, M. E. M. Gar-elnabi, Eitidal H. Khalafalla, F. I. Habani

Share this Article

Downloads: 110 | Weekly Hits: ⮙2 | Monthly Hits: ⮙11

Research Paper, Medicine Science, India, Volume 3 Issue 6, June 2014

Pages: 1877 - 1883

Effectiveness of Information Booklet regarding Home Care of Pacemaker among the Patients with Complete Heart Block

Sharmila Dake, Regina Dias

Share this Article



Top