Measurements Absorbed Doses to Some Organs during Head CT Imaging

T. M. Taha, S. H. Allehyani

Purpose to measure absorbed doses to brain, eyes and thyroid organs during head computed tomography imaging. Materials and Methods. Thermoluminscence dosimeters, TLD-100 placed inside the Head CT dosimetry phantom at four peripheral and central holes and irradiated to reference dose of CT beam. Results: The weighted dose conversion factor for TLD (s) at four peripheral holes and central hole of head phantom, at 120 kV and 400 mAs is generated. The mean absorbed doses to brain, eyes and thyroid during head CT protocol using phantom of human are found to be 1.02 mGy, 1.17 mGy and 0.99 mGy respectively. Conclusion the mean absorbed doses to brain, eyes and thyroid organs are lower than International Commission of Radiological Protection recommendations.

Keywords: Computed tomography CT, Head and body CT phantom, CTDI, Ray safe

Edition: Volume 9 Issue 1, January 2020

Pages: 350 - 352


How to Cite this Article?

T. M. Taha, S. H. Allehyani, "Measurements Absorbed Doses to Some Organs during Head CT Imaging", International Journal of Science and Research (IJSR), https://www.ijsr.net/search_index_results_paperid.php?id=ART20203958, Volume 9 Issue 1, January 2020, 350 - 352

50 PDF Views | 46 PDF Downloads

Download Article PDF



Similar Articles with Keyword 'Computed tomography CT'

Research Paper, Radiological Sciences, India, Volume 5 Issue 12, December 2016

Pages: 2064 - 2066

Imaging Evaluation of Mediastinal Tumours with Pathological Correlation

Dr. Girish Ghodadara, Dr. Purvi Desai, Dr. Rahul Sharma

Share this article

Survey Paper, Radiological Sciences, Saudi Arabia, Volume 7 Issue 8, August 2018

Pages: 488 - 492

Assessment of Radiation Dose from CT to Workers and Public from Common Diagnostic Investigations in Qatif Hospital

Fahad A. Mohamed, Gamareldein Alshikh, Mustafa Almeshal, Hassan AL-Sawad, Salman AL-faraj

Share this article

Case Studies, Radiological Sciences, India, Volume 7 Issue 3, March 2018

Pages: 1847 - 1850

MCTSI in the Evaluation of Acute Pancreatitis and its Prognostic Correlation

Dr Vikhyath Shetty, Dr Vinod Hegde

Share this article

Research Paper, Radiological Sciences, Sudan, Volume 7 Issue 8, August 2018

Pages: 459 - 466

Comparison between the First Order Statistical Analysis and Higher Order Statistical Analysis on Characterization of Brain Tumor on CT Images

Auis Bashir, Mohammed Garelnabi, Shazaly Khojaly, Magdi Hassan, Shaza Elfadil

Share this article

Research Paper, Radiological Sciences, Sudan, Volume 7 Issue 7, July 2018

Pages: 883 - 886

Classification of Brain Tumor Using Texture Analysis

Auis Mohammed, Mohammed Garelnabi, Shazaly Khojaly, Shaza Elfadil

Share this article

Similar Articles with Keyword 'CTDI'

Research Paper, Radiological Sciences, United Arab Emirates, Volume 5 Issue 11, November 2016

Pages: 1399 - 1402

Assessment of Radiation Dose Reduction when using AEC of MSCT in Sudan

Wadah M. Ali, Mogahid M. A Zidan

Share this article

Research Paper, Radiological Sciences, Saudi Arabia, Volume 9 Issue 1, January 2020

Pages: 350 - 352

Measurements Absorbed Doses to Some Organs during Head CT Imaging

T. M. Taha, S. H. Allehyani

Share this article

Top