International Journal of Science and Research (IJSR)

International Journal of Science and Research (IJSR)
Open Access | Fully Refereed | Peer Reviewed

ISSN: 2319-7064


Downloads: 133

Research Paper | Medical Science | India | Volume 8 Issue 1, January 2019


Analysis of Functional Outcome of Intrarticular Lower End Radius Fractures Treated by Closed Reduction with JESS Fixator with K-Wires versus Plating: A Comparative Study

Dr. Himanshu Tailor, Dr. Vikram Jasoliya


Abstract: distal radius, intraarticular fractures, JESS fixator PURPOSE: The purpose of this study was to compare the functional outcome in distal radius articular fractures treated by closed reduction through JESS fixator with k-wires versus volar-locking plating. METHODS: This study included patients with comminuted intra-articular distal radius fractures treated at SMIMER Surat.54 patients treated with either modality of treatment were analysed, who had been followed up for an average of was 8.9 months, (range: 3 months to 24 months). Prospective and retrospective data were gathered on patients, of which 30 were treated with JESS fixator with k-wire and 24 were treated with volar LCP. The 2 groups were compared for range of motion (ROM), strength, and functional outcome as measured by the Mayo wrist score. Sarmientos modification of Lindstorms criteria was used to compare the radiological outcome in both the groups. RESULTS: The mean passive wrist ROM at the final follow-up evaluation in ext fixation patients was 55 degrees extension and 67 degrees flexion, compared with 69 degrees extension and 77 degrees flexion in patients treated with volar LCP group. Whereas mean passive wrist ROM at the final follow-up evaluation in JESS fixation patients was 58 degrees supination and 46 degrees pronation, compared with 76 degrees supination and 64 degrees pronation in patients treated with volar LCP group. Final radiographic measurements for the JESS fixation group averaged 2.9 degrees volar tilt and 14.2 mm degrees radial inclination, with 5mm radial length. The Volar LCP group averaged 7.3 degrees volar tilt, 16.9 degrees radial inclination, with 9.75mm radial length. Radial length and volar tilt were significantly greater for the ORIF group when compared with the radial length. There was significant difference in the radiological and functional outcome of AO Muller type C fractures treated by volar LCP with respect to the JESS fixator group ( p value 0.009 and 0.026 respectively). There was no significant difference in the radiological and functional outcome of AO Muller type B fractures treated by volar LCP with respect to the JESS fixator group (p value 0.706 and 0.707 respectively). CONCLUSION: The use of ORIF with a volar fixed-angle implant resulted in stable fixation of the unstable (dorsally or volarly displaced intraarticular) distal articular fragments, allowing early postsurgical wrist motion (functional outcome) and having excellent to good radiological outcome; as compared with JESS fixator with K wires. However in type B (partial intraarticular fractures) fractures, Volar LCP and K- wire JESS fixator provide equivocal results and none is proved superior. Ligamentotaxis by JESS fixation provided favourable results in younger age group and in partial intra- articular type of distal radius fractures and requires atleast 4 cortical purchases on each side for effective stability. However long term follow-up is required to confirm our findings.


Keywords: distal radius, intraarticular fractures, JESS fixator


Edition: Volume 8 Issue 1, January 2019,


Pages: 2021 - 2026


How to Cite this Article?

Dr. Himanshu Tailor, Dr. Vikram Jasoliya, "Analysis of Functional Outcome of Intrarticular Lower End Radius Fractures Treated by Closed Reduction with JESS Fixator with K-Wires versus Plating: A Comparative Study", International Journal of Science and Research (IJSR), https://www.ijsr.net/get_abstract.php?paper_id=ART20194787, Volume 8 Issue 1, January 2019, 2021 - 2026

How to Share this Article?

Enter Your Email Address


Similar Articles with Keyword 'distal'

Downloads: 127

Research Paper, Medical Science, India, Volume 8 Issue 8, August 2019

Pages: 1256 - 1259

The Incidence and Further Outcome of Periprosthetic Supracondylar Femoral Fractures Post Total Knee Arthroplasty in India

Dr. Milan M Chaudhari, Dr. Kavyansh Bhan, Dr. Umang R Barot

Share this Article

Downloads: 160

Case Studies, Medical Science, India, Volume 8 Issue 7, July 2019

Pages: 328 - 331

Functional Outcome of Bicolumnar Plating in Fracture of the Distal Humerus in Elderly Adult: A Case Report

Dr. Kushwanth, Dr. Mohd Ismail Irfan

Share this Article

Similar Articles with Keyword 'intraarticular'

Downloads: 111

Comparative Studies, Medical Science, India, Volume 7 Issue 7, July 2018

Pages: 1502 - 1519

Prospective Open Case Control Comparative Study of Intraarticular Injection of Low and High Molecular Weight Viscosupplement in Osteoarthritis of Knee when given with and without Steroid and to assess the Use of C-arm in Target Delivery of Viscosupplement in Knee Joint Cavity

Samikrishnan Perumal, Maruthu Thurai Sambandam, Senthakrishna Thangaraj

Share this Article

Downloads: 160

Case Studies, Medical Science, India, Volume 8 Issue 7, July 2019

Pages: 328 - 331

Functional Outcome of Bicolumnar Plating in Fracture of the Distal Humerus in Elderly Adult: A Case Report

Dr. Kushwanth, Dr. Mohd Ismail Irfan

Share this Article

Similar Articles with Keyword 'fractures'

Downloads: 1

Research Paper, Medical Science, India, Volume 10 Issue 6, June 2021

Pages: 775 - 776

A Crunch in the ER - Case Report

Dr Ashish Nair

Share this Article

Downloads: 85

Case Studies, Medical Science, India, Volume 9 Issue 9, September 2020

Pages: 1210 - 1213

Effectiveness of Treatment of Orbital Floor Blowout Fractures with Autologus Iliac Crest Graft: A Report on 14 Cases

Sunil Shrivastava, Rohit Kumar Rai, Sharad Kumar, Abhishek Katara

Share this Article
Top