Views: 150 , Downloads: 129 | CTR: 86 % | Weekly Hits: ⮙2
Research Paper | Dental Science | Iraq | Volume 7 Issue 1, January 2018
Accuracy of Polyvinyl Siloxane Impression Material with Different Inter Implant Angulation
Yagthan M. Haider, Hasnahbinti Hashim, Mani Maran Ratnam, Norziha Yahaya
The suitability of a recommended material for implant impressions and the effects of implant angulation on the accuracy of the working cast remain debatable. Thus, evaluating the effect of impression materials with different implant angulations on the accuracy of impression is important (Cehreli et al., 2006). Four block shaped acrylic master models were fabricated with two implant analogs in each the first was placed at 0 angulation (reference implant) while the second was at 0, 5, 10, and 15 respectively. Sixty-four impressions were taken, 16 impressions for each of the four master casts, eight of them made using Aquasil impression material and the other eight impressions with Virtual impression material. IBM SPSS v.22 (SPSS Inc, Chicago) was demonstrated. according to the results material elasticity and inter-implant angulation had a combined effect on the accuracy of the implant impression (p =0.03). The inter-implant angulations were significantly associated with the impression accuracy (p= 0.027) regardless of the elasticity of the material. Post-hoc analysis using Tamhanes procedure showed a significant difference between angulation pairs of 0 - 10 and 0 - 15. The study demonstrated that the interaction between PVS impression materials of different elasticity (Virtual and Aquasil medium body) and the inter implant angulation of the analogs placed divergently produced a significant adverse effect on the impression accuracy. Regardless of material elasticity, the angulation of the implant analogs also adversely affects the impression accuracy
Keywords: Dental Implants, inter-implant angulation, elasticity, Vinyl Polysiloxane, Dimensional Measurement Accuracy
Edition: Volume 7 Issue 1, January 2018
Pages: 969 - 973
How to Cite this Article?
Yagthan M. Haider, Hasnahbinti Hashim, Mani Maran Ratnam, Norziha Yahaya, "Accuracy of Polyvinyl Siloxane Impression Material with Different Inter Implant Angulation", International Journal of Science and Research (IJSR), https://www.ijsr.net/search_index_results_paperid.php?id=ART20179039, Volume 7 Issue 1, January 2018, 969 - 973
150 PDF Views | 129 PDF Downloads
Similar Articles with Keyword 'Dental Implants'
Views: 46 , Downloads: 33 | CTR: 72 % | Weekly Hits: ⮙1
Research Paper, Dental Science, Brazil, Volume 10 Issue 2, February 2021
Pages: 1599 - 1607Digital Comparative Method for Analysis of Body Remodeling and Neoformation: Case Report
Norival F. Souza Jr, Helton Panisson, Guenther Schuldt Filho
Views: 66 , Downloads: 45 | CTR: 68 % | Weekly Hits: ⮙5
Research Paper, Dental Science, India, Volume 10 Issue 1, January 2021
Pages: 1445 - 1452Osseointegration of Dental Implants Bioactivated with Stem Cells and Prp-an invivo Study
Sadiq Mohammed Sabir Ali, Nishath Ayesha, Y. Mahadev Shastry, K. Mahendernath Reddy, Venkat Aditya, Jaya Krishna Babu
Views: 104 , Downloads: 68 | CTR: 65 % | Weekly Hits: ⮙3
Review Papers, Dental Science, India, Volume 9 Issue 12, December 2020
Pages: 749 - 756Demystifying Bruxism: A Review
Monika Nandan, Rudrax Jindal, Satheesh R, Rekha Gupta, Shubhra Gill
Views: 113 , Downloads: 77 | CTR: 68 % | Weekly Hits: ⮙2
Review Papers, Dental Science, India, Volume 9 Issue 9, September 2020
Pages: 1461 - 1465Guided Bone Regeneration in Immediate Dental Implants - Review
Dr. Koyel Bhowal, Dr. Samiran Ghosh
Views: 158 , Downloads: 112 | CTR: 71 % | Weekly Hits: ⮙3
Research Paper, Dental Science, Egypt, Volume 7 Issue 8, August 2018
Pages: 1527 - 1532Comparison of the Effect of Using Two Different Types of Bar Overdentures on the Supporting Structures of Mandibular Edentulous Ridge Area
Mohamed Z. Debis, Amr I. Badr, Emad M. Agamy, Gehan F. Mohamed
Similar Articles with Keyword 'elasticity'
Views: 118 , Downloads: 117 | CTR: 99 % | Weekly Hits: ⮙3
Research Paper, Dental Science, India, Volume 7 Issue 4, April 2018
Pages: 1177 - 1181Comparative Evaluation of Three Different Rotary NiTi File System with Different Generation for Root Canal Centric Ability Using CBCT: An in-vitro Study
Dr. Kailash Attur, Dr. Kamal Bagda, Dr. Kiran Vachhani, Dr. Jigar Parmar, Dr. Vivek Solanki, Dr. Riza Mansuri
Views: 137 , Downloads: 118 | CTR: 86 % | Weekly Hits: ⮙2
Research Paper, Dental Science, India, Volume 8 Issue 11, November 2019
Pages: 1644 - 1653Influence of Different Denture Base Resins on the Degree of De-Bonding in Terms of the Width of the Micro-Gap Created at Resin Base - Soft Liner Interface: An In-Vitro Study
Dr. Ankit Verma, Dr. Akanksha Kumari
Views: 150 , Downloads: 120 | CTR: 80 % | Weekly Hits: ⮙5
Research Paper, Dental Science, Iraq, Volume 7 Issue 3, March 2018
Pages: 1738 - 1745Evaluation the possibility of Bioactivation of Niobium and Titanium by Biomemtic Process
Ali AM, Intisar Jamil, L. Thair
Views: 150 , Downloads: 129 | CTR: 86 % | Weekly Hits: ⮙2
Research Paper, Dental Science, Iraq, Volume 7 Issue 1, January 2018
Pages: 969 - 973Accuracy of Polyvinyl Siloxane Impression Material with Different Inter Implant Angulation
Yagthan M. Haider, Hasnahbinti Hashim, Mani Maran Ratnam, Norziha Yahaya